Image Examples of Semiconductor Devices

Measurement & Diagnosis

Variety of image processing software simplifies analysis

Internal voids, delaminations and cracks in semiconductor devices such as QFP or TSOP can be inspected in non-destructive manner, and the inspection results can be output in image form. Furthermore, automatic Pass/Reject screening can be performed by digitalizing the results to binary data.

S-Image(TM)(PAT)
enlarge

S-Image(TM)(PAT)

S-Image (TM) sets the focus position on the sample surface at start of the scan, and moves down the focus position at each scan to generate a diagonal multi-focus image of the specimen. By simply selecting the brightest position of the inspection target where the focus is on the layer, correct focus position can be set.

Sイメージ(特許)
enlarge

Hitachi Auto-Lamino Image(TM)(PAT)

The function enables to generate up to 32 images of different layers with pre-set auto focusing function.

Image Index(TM)(PAT)
enlarge

Image Index(TM)(PAT)

Image Index TM is a menu all the image setup parameters can be saved with the generated image, which facilitates data management and re-measurement.

Waveform Display
enlarge

Waveform Display

Ultrasonic waveform at user-specified position on the image can be saved and displayed on this screen. Besides, waveform can be enlarged for detail analysis by simply dragging the target waveform area with a mouse.

Setting Parameter Display
enlarge

Setting Parameter Display

The window displays image setting parameter generated by S-Image (TM) or Image Index (TM).The latest setting parameter also can be displayed. Besides, inspection result can be added on the Image Index (TM).

Measurement Function
enlarge

Measurement Function

Measurement Function

Assessment Function
enlarge

Assessment Function

Delamination assessment can be performed by processing a waveform data at the user-pointed cursor position on the image. Furthermore, Polarity Comparison Image (PCM TM (PAT)) and binary image can be displayed based on the waveform data of the image.

Zoom Function
enlarge

Zoom Function

The image can be zoomed in and out in real time.

  • Standard image
  • Zoomed in image

Cross-sectional Image + Waveform Display
enlarge

Cross-sectional Image + Waveform Display

Multiple waveform windows and cross sectional images can be shown in one inspection result, which makes analysis and creation of inspection report easy.

3D Display
enlarge

3D Display

Two pieces of information out of Depth, Absolute amplitude, positive and negative polarity can be selected to generate a 3D image.

Multi-Display
enlarge

Multi-Display

Four different images can be obtained at one scan and displayed simultaneously on a monitor screen.

Detailed Setting Parameter
enlarge

Detailed Setting Parameter

Detailed setting parameter such as scanning area, image pixels, gate and image center position can be set for precise and efficient imaging.

Useful Image Index (TM) Function
enlarge

Useful Image Index (TM) Function

Image Index (TM) is a menu for saving all the inspection parameters together with the generated image. By simply selecting a desired Image Index (TM) to read set values, data management and re-measurement can be carried out with ease. (PAT.)

Time-of-Flight Image
enlarge

Time-of-Flight Image

Both echo level and time-of-flight information can be displayed. Depth of voids and shape of cracks can be clearly observed in this image.

Multi-Focus S-image (TM) Eliminates Complicated Focus Operation (PAT)
enlarge

Multi-Focus S-image (TM) Eliminates Complicated Focus Operation (PAT)

S-image (TM) (PAT.) allows simple focus operation. Click and select intended depth position on multi-focus S-image (TM); focus position is then set and allows quick inspection. Click an image to demonstrate image generation with S-Image (TM) function The demonstration shows [Image Index (TM) screen] - [Parameter Setting screen] - [Multi-Focus S-Image (TM) screen] - [Image center adjustment].

A Reflection Method Image


A Reflection Method Image

Reflection method is an inspection which ultrasonic probe will transmit and receive the ultrasonic wave reflected from the inspection sample. The intensity of reflected ultrasonic wave will be generated into a plane image. This method has advantage on the image resolution over other inspection methods. Also this method can receive the depth information.

Through Transmission Method


Through Transmission Method

Through Transmission method is a method similar to X-ray inspection, which transmits ultrasonic wave from one side of the specimen, receives it at the other side and create an image according to its reception energy. This method enables to inspect multi-layer structure at one time although the resolution of image is inferior compared to the reflection method.

Area Calculation (TM) Function
enlarge

Area Calculation (TM) Function

Area ratio of defects in the user specified dimensions (any area and shape on an image) is calculated.